Thinq Beyond: From measurement to intelligent control

Read more

Real-time spatial data as the basis for demand-driven lighting, climate control and building management

Measurement provides insight. Intelligent control ensures that a building can actually respond to those insights. Thinq collects real-time data from rooms and makes it available to other building systems. This allows lighting, ventilation, heating, and cooling to better align with actual occupancy and the indoor climate.

Thinq operates as an additional data layer within the existing building architecture. The existing building management system does not need to be replaced. Thinq measures real-time spatial data and transmits it to a gateway in real time. The gateway then passes the data to the BMS/BMS and any dashboards. Spatial data can be exchanged with a BMS/BMS, room controller, or HVAC installation via standard protocols such as BACnet, Modbus, and MQTT. Which connection is applied depends on the project architecture and the available equipment.

Demand-driven climate control

From fixed schedules to demand-driven climate control

A traditional building often runs largely on pre-set times. While this provides structure, it does not always account for varying room usage. Real-time occupancy and indoor climate data provide an additional basis for demand-driven control.

A room is empty
Occupancy data makes it visible when a room is not being used. The BMS/BMS can incorporate this information into the control of lighting and climate.

A room is filling up
People counting and CO₂ data provide information about the actual occupancy and the development of ventilation requirements.

The temperature changes
Temperature measurements are made available to the BMS/BMS. The HVAC control can use these values within the set control strategy.

The air quality changes
CO₂, TVOC, temperature, and humidity measurements show how the indoor climate is developing. This provides the building management system with real-time information from the space.

What data can Thinq provide?

What data can Thinq provide?

The available data depends on the sensors used and the configuration. Thinq can work with, among other things:

  • occupancy and motion data;
  • people-counting data;
  • CO₂ values;
  • TVOC values;
  • temperature;
  • relative humidity;
  • data regarding the status and control of lighting.

This data can be used individually or in combination. It is determined in advance which information is needed, where it is measured, and to which system the data is delivered.

What is required for connections and dashboards?

What is required for connections and dashboards?

Thinq and the lighting can function autonomously without a gateway. However, a gateway is required to connect Thinq to a BMS/BMS, HVAC installation, or dashboard. It receives the real-time measurement data from Thinq and passes it on to the linked systems.

An internet connection is required when a dashboard is shared with users. Cloud access is used when a gateway is present and floor plans or programming need to be managed remotely. This feature is currently under development.

Dashboard partners: Priva and Next Sense

Thinq collaborates with specialized partners for connections and dashboards. Priva is the hardware partner and provides the BMS connections for the HVAC installation. This allows the spatial data measured by Thinq to be made available for climate control via the gateway.

Next Sense is the software partner for analysis, reporting, and visualization. Thinq data, energy data, and data from submeters can be brought together in the dashboard, for example for electricity, gas, water, and lighting. An AI agent supports users in consulting and interpreting this information. Next Sense is an optional analysis and visualization layer and not a required component of Thinq.

Open connection with BMS, GBS and HVAC

Open connection with BMS, GBS and HVAC

Thinq is intended to collaborate with other systems within an existing building environment. Its strength lies in making additional spatial data available and connecting systems without unnecessarily replacing the existing BMS/BMS.

Various standard interfaces are available for data exchange:

BACnet
For data exchange with building management systems that support BACnet.

MQTT
For providing and exchanging data within a connected digital building environment.

Modbus
For integration with room controllers and HVAC equipment, including air conditioning systems and heat pumps.

The connection can be applied to ventilation systems, air conditioning, heat pumps, room controllers, and building management systems, among others. The actual integration depends on the supported protocols and data points of the connected equipment.

What are the benefits?

What are the benefits?

By making real-time spatial data available for building management, a control system is created that better aligns with the actual use of the building. This offers the following possibilities:

  • allowing installations to respond to presence and occupancy;
  • making indoor climate data per room available to the BMS/BMS;
  • basing lighting and climate control on the same real-time spatial situation;
  • maintaining and expanding existing building installations with a fine-grained data layer;
  • making data centrally available for monitoring, visualization, and further analysis.

The concrete result depends on the chosen control strategy, the settings, the use of the rooms, and the capabilities of the connected installations.

Intelligent control becomes stronger when various Thinq functions are applied together. Presence detection provides information about the use of the space. People counting provides insight into occupancy. Daylight compensation, dimming levels, and scheduling regulate the light based on daylight, usage, and time. The same spatial data can also be made available to the building management system.

This creates a single, coherent information base, while each connected system maintains its own function and control strategy.

Technical points of attention

  • Determine in advance which measurement data and data points are required for the desired control.
  • Check which protocols are supported by the BMS/BMS, the room controller, and the HVAC equipment.
  • Establish whether Thinq only provides data or also exchanges commands with the connected equipment.
  • Align sensor placement and configuration with the rooms and the information requirements.
  • Configure and test the entire data chain during commissioning.
  • Verify the operation of the control strategy in the building’s practical situation.

What may we make smart?

We are always at your service and are happy to assist you with your inquiry. Please contact us through one of the methods below.

Or send an email

This field is for validation purposes and should be left unchanged.

Share this list
Request a quote